Skip to main content

Redundant Automation Systems – Need and Advantages

 Redundancy in the English language means “the state of being not or no longer needed or useful” but in Industrial Automation systems, it has an important and critical function to execute.

So today are we going to understand the concept of Redundancy and how could this concept help us to build a better Automation solution.


What is meant by the Redundant Automation System?
Redundancy is about having backup components in a system that can take over if and when the primary components fail.

Redundant Automation Systems basically consist of two major elements (Master & slave) or we can call them (primary component & secondary component).

These two components are supposed to perform the same function but they have some priorities.

The primary component is responsible for handling the function and once it fails the backup (secondary) component takes its place to handle the same function without any stoppage.

The Need for Redundancy
The objective of using redundant automation systems is to reduce the risk of production losses, regardless of whether the losses are caused by an error or as a result of maintenance work.


The higher the costs of downtimes, the more worthwhile it is to use a redundant system.
Notice that:

“The generally higher investment costs of redundant systems are quickly returned by the avoidance of production losses.”

Example

A common term in redundancy is “bump”.  A “bump” is an interruption in the process such as an unplanned line stoppage, or machine shutdown. Every industrial process is different in terms of what the consequences of a bump are.

As an example:
If you are dealing with a “Gas Metering Station” that is responsible for the accurate metering of natural gas flow, I suppose that you have already know how this process is critical and should be done as accurately as possible.

So, in case of any miscommunication between the flow computer and the measuring instrument (Meter, Transmitters) that would cost you a lot of money as the flow will not be measured.

Here in such a situation, you have to make a redundant system consisting of two or even three Flow Computers, all of them make the same function (measuring gas flow) so when one of them has a “bump” situation, Automatically the other flow computer will start to handle the process and save the measuring readings and data.

System Nodes that Requires Redundancy
Here are some of the system sections that need to be covered with redundancy:

  • Physical Networks
  • Network Interface Cards (NIC)
  • PLC’s
  • Output control devices
  • OPC Server software
  • Physical servers
  • Power sources/UPS
Main Advantage of a Redundant System
Achieving redundancy requires a good deal of effort, and it may deter some organizations from putting in the extra work.

But the benefits of redundancy will build trust from the users and make the overall infrastructure more reliable and better than ever. The first benefit that a redundant network offers is uptime or the lack of downtime.

A system that is always up and ready to go is crucial for many (if not all) different industries. The cost of downtime costs the company an average of $5,600 every minute and an average of $300,000 every hour. This number can even be as much as $540,000 per hour.

This isn’t even mentioning the critical operations such as hospitals. System redundancy can prevent downtime that many companies cannot afford.

And on the other hand, we will find that these systems are expensive and it has a kind of complexity but regarding their benefits, for sure the overall system is helpful.

Comments

Popular posts from this blog

What is a Torbar? – Averaging Pitot Tubes

 The Torbar is employed for flow measurement of liquids, gases, or steam in circular, square, or rectangular section ducts for large flow rates. The Torbar is an insertion type multi-port self-averaging primary sensor for flow measurement. Torbar TORBAR is a set of Pitot tubes mounted on a bar across the pipeline with no moving parts. An averaging Pitot tube is a technology, while TORBAR is a manufacturing brand name. There are several brands available in the market with VERABAR, ANNUBAR, etc. Averaging Pitot Tube Principle Purpose Averaging Pitot tube can be employed when the average velocity of the flow profile, rather than the velocity in a specific point in the cross-section is desired. Averaging Pitot Tubes Principle It measures the differential pressure between the static pressure tap and the tap of full pressure of a stream. Thus such magnitude of differential pressure is directly proportional to the square of the flow rate. Working The TORBAR is designed in such a way that ...

Ferrules and Cross Ferruling

 Ferrules are identification labels provided for every wire terminations in an instrument, equipment, or electrical/instrumentation control panels. These tube-shaped sleeves can be inserted easily on each individual wire in a multi-core cable. In earlier days fixed digits/letters are used as ferrules, but now Instrumentation engineers/technicians prints out desired ferrules by using a ferrule printing machine. Typical Ferrule The numbers/ letters on the ferrules will be given as per the approved electrical hook up or loop diagrams. This helps technicians to easily identify a particular loop/wiring from a series of terminal blocks and to troubleshoot the desired terminal connection. Separate numbers on the ferrules distinguish the positive and negative polarities of wires, thus ensure the polarity protection of the instrument. Cross Ferruling  As a wire is connected on its both ends, it is quite useful to use a cross reference method for wire identification. Unlike normal ferru...

Thermowell Insertion and Immersion Length

 The thermowell is the industrial housing for temperature elements like RTD or thermocouple or temperature gauges. Thermowell is directly exposed to process fluid/media. Inside the thermowell, element/gauge is installed. Thermowell transfers the heat to the temperature element. Depending upon the element type, the fluid temperature can be known. So Thermowell protects the temperature element against harsh conditions and process fluid. It enables removal of the temperature element for replacement, repair, or testing without affecting the process system. Generally, thermowells are provided with all-temperature Elements like RTD or Thermocouple or temperature gauge. A few exceptions would be bearing RTD, skin type thermocouple, air duct thermometer, etc where thermowell is not applicable / required. When the thermowell assembly is inserted into the pipe, it is subjected to vibration. This vibration is caused by vortices to be generated alternately on either side of the thermowell. The...