Communication between Wincc and Tia Portal

 This article is about communication between WinCC and TIA portal using simple programming examples and screenshots.

Wincc and Tia Portal

Step 1:

Open TIA PORTAL. Create a new project. Configure the devices and open programming environment.

Step 2:

The same way, create a new project in HMI. I already created an article on it. Read the article before proceed here.

Step 3:

From the above two steps, we created new projects in Tia Portal and WinCC.

After creating new projects, let’s move to establish communication between them.

As shown in the below window click on option “HMI” and expand it. Double click on “device configuration”.


Step 4:

Click on “network view”. Here, you can see PLC is added to the network as we already have configured while creating a new project.

Make sure that you select CPU and HMI have which contains the same port for communication. Here, I have select HMI and CPU which have the same PROFINET port in common.

Step 6:
Now to check communication established properly select any one HMI or PLC and do right click on it to open the selection menu as shown in the below window.
Click on “compile” and select “hardware rebuild all”.

Step 7:
You are done with communication. To check IP address select “HMI” as shown in the below window. Click on “device view”.

Step 8:
Following window will pop-up. Click on green color Profinet port. In the “general” section, select the “Profinet interface” where you can find an IP address and you can make changes with your application.

Step 9:
Do follow the same procedure for CPU to check an IP address.

END


Comments

Popular posts from this blog

Ferrules and Cross Ferruling

 Ferrules are identification labels provided for every wire terminations in an instrument, equipment, or electrical/instrumentation control panels. These tube-shaped sleeves can be inserted easily on each individual wire in a multi-core cable. In earlier days fixed digits/letters are used as ferrules, but now Instrumentation engineers/technicians prints out desired ferrules by using a ferrule printing machine. Typical Ferrule The numbers/ letters on the ferrules will be given as per the approved electrical hook up or loop diagrams. This helps technicians to easily identify a particular loop/wiring from a series of terminal blocks and to troubleshoot the desired terminal connection. Separate numbers on the ferrules distinguish the positive and negative polarities of wires, thus ensure the polarity protection of the instrument. Cross Ferruling  As a wire is connected on its both ends, it is quite useful to use a cross reference method for wire identification. Unlike normal ferru...

What is a Torbar? – Averaging Pitot Tubes

 The Torbar is employed for flow measurement of liquids, gases, or steam in circular, square, or rectangular section ducts for large flow rates. The Torbar is an insertion type multi-port self-averaging primary sensor for flow measurement. Torbar TORBAR is a set of Pitot tubes mounted on a bar across the pipeline with no moving parts. An averaging Pitot tube is a technology, while TORBAR is a manufacturing brand name. There are several brands available in the market with VERABAR, ANNUBAR, etc. Averaging Pitot Tube Principle Purpose Averaging Pitot tube can be employed when the average velocity of the flow profile, rather than the velocity in a specific point in the cross-section is desired. Averaging Pitot Tubes Principle It measures the differential pressure between the static pressure tap and the tap of full pressure of a stream. Thus such magnitude of differential pressure is directly proportional to the square of the flow rate. Working The TORBAR is designed in such a way that ...

Dissolved Oxygen Analyzer Working Principle

 What is dissolved oxygen ? Dissolved oxygen refers to oxygen dissolved in water. Its concentration is expressed as the amount of oxygen per unit volume and the unit is mg/L. Biologically, oxygen is an essential element for respiration of underwater life and also acts as a chemical oxidizer. The solubility of oxygen in water is affected by water temperature, salinity, barometric pressure, etc. and decreases as water temperature rises. Measurement of dissolved oxygen by the membrane electrode method The membrane electrode method measures a diffusion current or reduction current generated by the concentration of dissolved oxygen or partial pressure of oxygen to obtain the concentration of dissolved oxygen. This method is not affected by the pH value of water being measured, oxidation and reduction substances, color, turbidity, etc. and the measurement method offers good reproducibility. When a sensor is inserted into water, an air layer forms on the membrane (Teflon membrane). The ox...