Non-contact Vibration Measurement

 Types of Non – Contact Vibration Measurement

Path Measurement

  • Capacitance
  • Eddy Current
  • Hall Effect
  • Optical

Speed Measurement

Laser-Doppler vibrometer

  • Seismometer
  • Acceleration measurement

Path measurement

Capacitive Principle

The capacitive principle can be applied to non-contact vibration measurement, if the vibrating object or a relevant part of it is useable as a plate of a capacitor.

In order to do measurements, a second plate is needed. Now the whole setup works like any common capacitor. The variation of the distance of the two plates is proportional to the capacity.

An AC supply is connected to the capacitor. Depending on the distance between the plates, a specific amplitude can be recognized by the sensor which can be used for further processing.

The measuring stroke reaches from several μm μm to mm with a resolution of some nm. The band of frequencies lies between 0 and 6 kHz.

However this non-contact method is not feasible for application in high quantities and must be adapted to the individual case.

Eddy current sensor

In eddy current sensors, the displacement measurement of vibrations is limited to metallic objects or at least objects with a metallic surface.

The sensor consists of a coil which is connected to an AC supply. This configuration develops an electromagnetic field that in turn causes eddy currents within the metallic object.

These eddy currents interfere with the electromagnetic field and result in a measureable dissipation. Possible path measurements are between 0.5 and 80 mm.

Here the resolution lies somewhere between nm and μm μm . The band of frequency ranges between 1 Hz and 100 kHz

Hall sensor
The Hall sensor uses the Hall-effect for the non-contact path measurement. To that end a small permanent magnet has to be fixed on the measured object.

As soon as vibrations occur, an electric signal can be detected through measuring the effect of the Lorentz force.

The output signal is proportional to the covered path. However the non-linear characteristic curve and the high sensibility to environmental impacts results in a limited usability.
Optical sensor
Optical sensors use lasers to detect changes in distance. In addition to a laser, beam splitters, a reflector, a Bragg cell and a photo detector are necessary to carry out measurements.

These devices are needed to obtain two beams, a measuring beam and a reference beam. The measuring beam is focused on the vibrating object. Its reflection merges with the reference beam and starts to interfere.

The generated interference pattern can be decoded by the photo detector. The range of an optical sensor lies within few millimetres with a resolution in the region of nanometres.

Speed measurement
Laser-Doppler vibrometer
The Laser-Doppler vibrometer (LDV) uses the Doppler frequency shift for non-contact speed measurement.

In principle, it consists of a laser, beam splitters, a reflector, a Bragg cell and a photo detector. The coherent laser light is split into a measuring beam and the reference beam by means of polarisation.

The measuring beam is projected onto the vibrating object and is reflected on its surface. The reference beam is used to be send through a Bragg cell for a frequency shift.

This frequency shift allows the detection of motion direction later. The interference of both beams leads to a frequency modulated signal. Various demodulation methods are able to translate the signal into path or speed information.

Commercial LDVs have a frequency range between 0 Hz and 30 MHz and can follow vibration speeds from 100 nm/s up to 20 m/s.
Acceleration measurement
So far there is no way known to gain acceleration data directly. It is possible to receive this data by derivation from the speed measurement.

However measurement noise has a great effect on the quality of the derived data. Thus it is not always possible or useful to do so.

Vibration Sensors Characteristics






Comments

Popular posts from this blog

Ferrules and Cross Ferruling

 Ferrules are identification labels provided for every wire terminations in an instrument, equipment, or electrical/instrumentation control panels. These tube-shaped sleeves can be inserted easily on each individual wire in a multi-core cable. In earlier days fixed digits/letters are used as ferrules, but now Instrumentation engineers/technicians prints out desired ferrules by using a ferrule printing machine. Typical Ferrule The numbers/ letters on the ferrules will be given as per the approved electrical hook up or loop diagrams. This helps technicians to easily identify a particular loop/wiring from a series of terminal blocks and to troubleshoot the desired terminal connection. Separate numbers on the ferrules distinguish the positive and negative polarities of wires, thus ensure the polarity protection of the instrument. Cross Ferruling  As a wire is connected on its both ends, it is quite useful to use a cross reference method for wire identification. Unlike normal ferru...

What is a Torbar? – Averaging Pitot Tubes

 The Torbar is employed for flow measurement of liquids, gases, or steam in circular, square, or rectangular section ducts for large flow rates. The Torbar is an insertion type multi-port self-averaging primary sensor for flow measurement. Torbar TORBAR is a set of Pitot tubes mounted on a bar across the pipeline with no moving parts. An averaging Pitot tube is a technology, while TORBAR is a manufacturing brand name. There are several brands available in the market with VERABAR, ANNUBAR, etc. Averaging Pitot Tube Principle Purpose Averaging Pitot tube can be employed when the average velocity of the flow profile, rather than the velocity in a specific point in the cross-section is desired. Averaging Pitot Tubes Principle It measures the differential pressure between the static pressure tap and the tap of full pressure of a stream. Thus such magnitude of differential pressure is directly proportional to the square of the flow rate. Working The TORBAR is designed in such a way that ...

Dissolved Oxygen Analyzer Working Principle

 What is dissolved oxygen ? Dissolved oxygen refers to oxygen dissolved in water. Its concentration is expressed as the amount of oxygen per unit volume and the unit is mg/L. Biologically, oxygen is an essential element for respiration of underwater life and also acts as a chemical oxidizer. The solubility of oxygen in water is affected by water temperature, salinity, barometric pressure, etc. and decreases as water temperature rises. Measurement of dissolved oxygen by the membrane electrode method The membrane electrode method measures a diffusion current or reduction current generated by the concentration of dissolved oxygen or partial pressure of oxygen to obtain the concentration of dissolved oxygen. This method is not affected by the pH value of water being measured, oxidation and reduction substances, color, turbidity, etc. and the measurement method offers good reproducibility. When a sensor is inserted into water, an air layer forms on the membrane (Teflon membrane). The ox...