Skip to main content

RF Level Switches Working Principle

 RF level sensors are the Capacitance level detectors which are sometimes called as admittance level sensors. These sensors make use of radio frequency balanced impedance bridge circuit to find out whether the probe is in touch with the process material whose level is going to be detected. “Calibration is done when material is not in contact with the probe. The bridge is balanced by turning the adjustment pot to find the bridge balance threshold. When material comes in contact with the probe, the bridge becomes unbalanced and the comparing circuit realizes the change.” RF level sensors usually work in the low radio frequency megahertz range and measure admittance i.e. conductance in an alternating current circuit which changes with level. Their sensitivity is measured in pico-farads i.e. pF.

A horizontally mounted RF level switch is shown in the figure below.

It consists of a conductive probe which serves as one of the capacitor plate, and the vessel wall which forms the other plate of capacitor since it is also prepared from a conductive material. The isolation between these two plates of capacitor is provided via an insulating process material having low dielectric constant. Now, for measurement purpose, an RF signal is applied between the two capacitor plates which causes a little flow of current from the conductive probe to the vessel wall via process material. The probe works as an antenna to sense the frequency. “When the level in the tank drops and the probe is exposed to the even less conductive vapors, the dielectric constant drops. This causes a drop in the capacitance reading and a minute drop in current flow. This change is detected by the level switch’s internal circuitry and translated into a change in the relay state of the level switch.”

The most widely used probe design includes a stainless steel rod having a diameter of 1 or 1/2 inches. This design is considered appropriate for nearly all non-conductive and non-corrosive substances. The most popular low-dielectric insulating materials used with the probe consist of Nylon or Ryton. The electronic circuitry of the probe has a solid state construction and it mainly carries out following tasks:

It filters and corrects the input power supply
It produces the required radio frequency signal
It detects the variations in flow of current
It manages and controls interface devices like relays, analog signal generators and display meters.
The circuitry is also granted with provisions to regulate sensitivity and time delays with the help of potentiometer adjustments.

In general, an RF Admittance level transmitter works in an identical fashion as a Capacitance transmitter. However, there are two major modifications in the design which include the oscillator buffer and the chopper drive circuits. These two circuits enable separate determination of resistance and capacitance. This is particularly useful in coating applications for level detection. Since, according to the physical laws, the resistance and capacitance of any coating have same value, the error produced due to the coating can be avoided by measuring and deducting it from the overall output. The resulting output is thus very accurate despite of the presence of coating on the probe. However, “RF admittance is intrusive. Insulating granular measurements require special considerations, such as the moisture range and location of the sensing element to minimize errors caused by probe movement.” In case of insulators having varying dielectric constants, the accurate level measurement can be accomplished only if the material under measurement is homogeneous. However, various advanced RF transmitter designs have been made available which offer high class stability, accuracy and distant communication. For best performance and selection of RF level sensors, one must have fairly accurate idea of the electrical nature of the process material.

Advantages

They work suitably for level detection in case of both liquids and massive solids.
They can withstand high temperatures, high pressures, high vibrations and several other coarse operating conditions owing to their strong and robust design.
Since they consist of no moving parts, they are free from wear, plug or jam troubles.
They are easy to install and calibrate.
The length of probe in case of RF level sensors can be easily customized depending upon the application.
They are the most flexible means to provide continuous level measurement.
They operate over a broad range of pressure which varies from vacuum to 10,000 psi and temperature ranging from cryogenics to around 850oC.
Typical Applications

Major application areas of RF level sensors include:

They are widely employed for level detection in case of liquids such as water or wastewater, fuels, petroleum products, acids, caustics, corn Syrup etc.
They can also be applied for level measurement in case of interfaces between liquids such as oil and water, crude and brine, foam and liquid etc.
They can be used with dry and bulk solids too, for instance, fly ash, cement and sand, plastics, flour and grain, powders, carbon black, wood chips etc.


Comments

Popular posts from this blog

Ferrules and Cross Ferruling

 Ferrules are identification labels provided for every wire terminations in an instrument, equipment, or electrical/instrumentation control panels. These tube-shaped sleeves can be inserted easily on each individual wire in a multi-core cable. In earlier days fixed digits/letters are used as ferrules, but now Instrumentation engineers/technicians prints out desired ferrules by using a ferrule printing machine. Typical Ferrule The numbers/ letters on the ferrules will be given as per the approved electrical hook up or loop diagrams. This helps technicians to easily identify a particular loop/wiring from a series of terminal blocks and to troubleshoot the desired terminal connection. Separate numbers on the ferrules distinguish the positive and negative polarities of wires, thus ensure the polarity protection of the instrument. Cross Ferruling  As a wire is connected on its both ends, it is quite useful to use a cross reference method for wire identification. Unlike normal ferru...

PLC Program for Mixing Tank

 Create a ladder diagram for controlling a batch mixing process. Implement a PLC program for mixing tank or Mixing Process using PLC Ladder Logic. PLC Program for Mixing Tank Fig : Mixing tank A tank is used to mix two liquids. The required control circuit operates as follows: A. When the START button is pressed, solenoids A and B energize. This permits the two liquids to begin filling the tank. B. When the tank is filled, the float switch trips. This de-energizes solenoids A and B and starts the motor used to mix the liquids together. C. The motor is permitted to run for 1 minute. After 1 minute has elapsed, the motor turns off and solenoid C energizes to drain the tank. D. When the tank is empty, the float switch de- energizes solenoid C. E. A STOP button can be used to stop the process at any point. F. If the motor becomes overloaded, the action of the entire circuit will stop. G. Once the circuit has been energized, it will continue to operate until it is manually stopped. Solution...

What is a Torbar? – Averaging Pitot Tubes

 The Torbar is employed for flow measurement of liquids, gases, or steam in circular, square, or rectangular section ducts for large flow rates. The Torbar is an insertion type multi-port self-averaging primary sensor for flow measurement. Torbar TORBAR is a set of Pitot tubes mounted on a bar across the pipeline with no moving parts. An averaging Pitot tube is a technology, while TORBAR is a manufacturing brand name. There are several brands available in the market with VERABAR, ANNUBAR, etc. Averaging Pitot Tube Principle Purpose Averaging Pitot tube can be employed when the average velocity of the flow profile, rather than the velocity in a specific point in the cross-section is desired. Averaging Pitot Tubes Principle It measures the differential pressure between the static pressure tap and the tap of full pressure of a stream. Thus such magnitude of differential pressure is directly proportional to the square of the flow rate. Working The TORBAR is designed in such a way that ...