Skip to main content

Difference between Invasive & Non-invasive and Intrusive & Non-intrusive

 Invasive devices have transducers which come into contact with the flowing fluid. They are also called ‘wetted’ transducers.

Non–invasive transducers do not come into contact with the fluid and are placed on the outside of the pipe. Intrusive devices protrude into the flow and distort the flow profile, as can be seen in the top two diagrams.

The distortion often leads to mis-measurement by introducing asymmetry to the velocity profile.

Different devices can be intrusive but non-invasive or even invasive but non-intrusive. For example, the ultrasonic meters are both non-intrusive and non-invasive.

The reason non-intrusive and especially non-invasive flow meters are so popular is because they do not protrude into the flow, do not come in to contact with fluid and do not generate any pressure losses.

The below table will give us a clarity about Invasive & Non-Invasive and similarly Intrusive & non-Intrusive.

Invasive Type :

Sensor will be in contact with the process flow

Non-Invasive Type :

Sensor will be mounted externally and there will be NO contact with process flow.

Intrusive Type :

Sensor will be placed/mounted in the pipeline but either it can be in-contact or no-contact with the process flow.

Non-Intrusive Type :

Sensor will be placed/mounted outside the pipeline but either it can be in-contact or no-contact with the process flow.

Non intrusive devices do not interfere with the flow profile. No pressure drop is observed meaning that these devices are more cost effective to operate. They are also non-invasive which means they do not come into contact with the fluid being measured.

This is very beneficial when measuring dangerous or corrosive fluids that could damage sensor heads. It also means the transducers can be used alongside heavily fouling fluids and not be affected. This extends the life of the transducers, again saving money.

There is no need to break into the pipeline to install these meters which means they can be installed without shutting down the process. This makes them ideal for use on a number of different lines for verification purposes as they are easily portable. There is no chance of leakage or contamination.

The turn down ratio is the range at which a meter can operate within its stated uncertainty levels. It is written as a ratio of the highest flow rate in its range compared to the lowest.

For a more traditional flow meter such as a differential pressure meter or a turbine meter, the turndown ratio is around 10:1. A non-invasive ultrasonic meter however can have a turndown ratio of up to 400:1.

There are no moving parts associated with ultrasonic meters and hence no wear and tear. A turbine meter may have to be maintained in order to achieve peak performance but this is not the case with non-invasive technology.

This low maintenance means it will continue to deliver a consistent reading for as long as transducers are working. And even if they fail then they can be easily replaced with new ones without shutting down the process.


Comments

Popular posts from this blog

Ferrules and Cross Ferruling

 Ferrules are identification labels provided for every wire terminations in an instrument, equipment, or electrical/instrumentation control panels. These tube-shaped sleeves can be inserted easily on each individual wire in a multi-core cable. In earlier days fixed digits/letters are used as ferrules, but now Instrumentation engineers/technicians prints out desired ferrules by using a ferrule printing machine. Typical Ferrule The numbers/ letters on the ferrules will be given as per the approved electrical hook up or loop diagrams. This helps technicians to easily identify a particular loop/wiring from a series of terminal blocks and to troubleshoot the desired terminal connection. Separate numbers on the ferrules distinguish the positive and negative polarities of wires, thus ensure the polarity protection of the instrument. Cross Ferruling  As a wire is connected on its both ends, it is quite useful to use a cross reference method for wire identification. Unlike normal ferru...

What is a Torbar? – Averaging Pitot Tubes

 The Torbar is employed for flow measurement of liquids, gases, or steam in circular, square, or rectangular section ducts for large flow rates. The Torbar is an insertion type multi-port self-averaging primary sensor for flow measurement. Torbar TORBAR is a set of Pitot tubes mounted on a bar across the pipeline with no moving parts. An averaging Pitot tube is a technology, while TORBAR is a manufacturing brand name. There are several brands available in the market with VERABAR, ANNUBAR, etc. Averaging Pitot Tube Principle Purpose Averaging Pitot tube can be employed when the average velocity of the flow profile, rather than the velocity in a specific point in the cross-section is desired. Averaging Pitot Tubes Principle It measures the differential pressure between the static pressure tap and the tap of full pressure of a stream. Thus such magnitude of differential pressure is directly proportional to the square of the flow rate. Working The TORBAR is designed in such a way that ...

The Method and Process of Siemens PLC Hardware Configuration

 The hardware configuration of Siemens PLC can usually adopt the following methods and processes: Determine control tasks and system requirements: Before hardware configuration, it is necessary to clarify the tasks and requirements of the control system, including the requirements for input and output points, control accuracy, speed, and safety. Select the PLC model and module: According to the control task and requirements, select the appropriate PLC model and module, including CPU, I/O module, communication module, power supply module, etc. Assemble the cabinet and install the modules: According to the selected PLC model and module, assemble the cabinet and install the modules, pay attention to the installation sequence, cable wiring, wiring method, etc. Connect the input and output devices: connect the input and output devices with the input and output modules of the PLC, you need to pay attention to the correctness, stability and safety of the wiring. Perform software configura...